Where the register points next
Each step below is one supersession training.gov.au publishes between two products. The label on the rail is the equivalence the register declares for that step — not our reading of it.
What the register says changed
These are the mapping notes training.gov.au attaches to each supersession, quoted as the register writes them. They are the only public record of what actually changed between two versions.
CPC50611CPC50612≠not equivalent6 February 2013
Revised qualification deemed not equivalent to CPC50611 Change to core units: • CPCPFS5000A deleted and replaced with CPCSFS5001A • CPCPFS5002A deleted and replaced with CPCSFS5007A Core and elective units revised resulting in a number of unit identifier changes
CPC50612CPC50620=equivalent26 November 2020
The register records this supersession but attaches no note on what changed.
Is CPC50612 on your scope?
This page is the register's record of one product. What it cannot tell you is whether CPC50612 sits on your own scope today, or what else on that scope has moved without anyone noticing. Enter your RTO number and we read every product on your live scope against training.gov.au and tell you which ones are superseded and which replacements the register flags not equivalent.
Whether a supersession requires anything of you, and what, sits with you and your regulator. This page maps what the register records; it does not make that judgement. If the difference between an equivalent and a non-equivalent replacement is the question, we wrote it up in equivalent vs not equivalent.
What CPC50612 is made of
training.gov.au lists 41 units for CPC50612: 30 core and 11 elective. The register does not publish a completion rule in units for this product, so we do not state one. How many of the electives are required is in the packaging rules on training.gov.au.
Core units 30 listed
| Code | Unit | In this product |
|---|---|---|
| BSBITU201A | Produce simple word processed documents | !not current |
| BSBITU202A | Create and use spreadsheets | !not current |
| BSBITU301A | Create and use databases | !not current |
| BSBWRT401A | Write complex documents | !not current |
| CPCCBC4012B | Read and interpret plans and specifications | !not current |
| CPCPCM4013A | Produce 2-D architectural drawings using CAD software | !not current |
| CPCPCM4014A | Prepare simple sketches and drawings | !not current |
| CPCPCM5010A | Design complex sanitary plumbing and drainage systems | !not current |
| CPCPCM5011A | Design complex cold water systems | !not current |
| CPCPCM5012A | Design complex stormwater and roof drainage systems | !not current |
| CPCPCM5013A | Design complex (non-solar) heated water systems | !not current |
| CPCPDR4011B | Design and size sanitary drainage systems | !not current |
| CPCPDR4012B | Design and size stormwater drainage systems | !not current |
| CPCPDR4013B | Design and size domestic treatment plant disposal systems | !not current |
| CPCPFS4024A | Design residential and domestic fire sprinkler systems | !not current |
| CPCPGS4011C | Design and size consumer gas installations | !not current |
| CPCPPS5000B | Design gas bulk storage systems | !not current |
| CPCPPS5001B | Design industrial gas systems | !not current |
| CPCPPS5002B | Design gas reticulation systems | !not current |
| CPCPPS5023A | Design solar water heating systems | !not current |
| CPCPPS5024A | Conduct a water audit and identify water-saving initiatives | !not current |
| CPCPPS5025A | Design grey water re-use systems | !not current |
| CPCPPS5026A | Design rainwater collection, storage, distribution and re-use systems | !not current |
| CPCPPS5028A | Design trade waste pre-treatment systems | !not current |
| CPCPPS5030A | Design pump systems | !not current |
| CPCPPS5032A | Design siphonic stormwater drainage systems | !not current |
| CPCPSN4011B | Design and size sanitary plumbing systems | !not current |
| CPCPWT4011B | Design and size heated and cold water services and systems | !not current |
| CPCSFS5001A | Define scope and hazard level of fire systems design projects | !not current |
| CPCSFS5007A | Create detailed designs for hydrant and hose reel systems | !not current |
Elective units 11 listed
| Code | Unit | In this product |
|---|---|---|
| CPCPCM5014A | Design sewer infrastructure systems | !not current |
| CPCPFS5011A | Design fire sprinkler systems | !not current |
| CPCPMS5010A | Design steam generation and distribution systems | !not current |
| CPCPMS5011A | Design air conditioning and ventilation systems | !not current |
| CPCPMS5012A | Design sound attenuated hydraulic services | !not current |
| CPCPMS5013A | Design hydronic heating and cooling systems | !not current |
| CPCPPS5014A | Locate and maintain piping systems | !not current |
| CPCPPS5015B | Inspect plumbing and drainage systems | !not current |
| CPCPPS5027A | Design irrigation systems | !not current |
| CPCPPS5033A | Design vacuum sewerage systems | !not current |
| CPCSUS5001A | Develop workplace policies and procedures for sustainability | !not current |
Core and elective are the register's own flags on the unit grid of the release read here. "Not current" means training.gov.au no longer recommends that unit for use inside this product — it does not say anything about the product itself.
Source: this product on training.gov.au, Australia's national training register — or go straight to the units it requires. The rule itself is item 14 of F2025L00355, and ASQA publishes the extensions it has granted. Read on 28 August 2026 UTC. Every code, title, date, status and equivalence flag on this page is the register's; nothing here is estimated or inferred, and where the register publishes nothing we say so.
Every CPC training product on the register · Search all training products
Is CPC50612 still on your scope? Type your RTO code and get the free breakdown — every superseded product on your live scope, and whether the register flags each replacement equivalent.
No account, no card. We never ask for anything about your learners. Your address gets this one report — no list, no marketing — and the scope watch only if you tick the box, with one click to stop it.