Where the register points next
training.gov.au points at nothing after MSL40122: it is the current product, and no replacement is listed.
What the register says changed
These are the mapping notes training.gov.au attaches to each supersession, quoted as the register writes them. They are the only public record of what actually changed between two versions.
Is MSL40122 on your scope?
This page is the register's record of one product. What it cannot tell you is whether MSL40122 sits on your own scope today, or what else on that scope has moved without anyone noticing. Enter your RTO number and we read every product on your live scope against training.gov.au and tell you which ones are superseded and which replacements the register flags not equivalent.
Whether a supersession requires anything of you, and what, sits with you and your regulator. This page maps what the register records; it does not make that judgement. If the difference between an equivalent and a non-equivalent replacement is the question, we wrote it up in equivalent vs not equivalent.
What MSL40122 is made of
training.gov.au lists 46 units for MSL40122: 4 core and 42 elective. To complete it, the register publishes a rule of 4 core units plus 12 electives — 16 units in all.
Core units 4 listed
Elective units 42 listed
| Code | Unit | In this product |
|---|---|---|
| BSBLDR413 | Lead effective workplace relationships | ●current |
| FBPFST4004 | Perform microbiological procedures in the food industry | ●current |
| FBPFSY4001 | Supervise and maintain a food safety plan | ●current |
| FBPTEC4009 | Identify the physical and chemical properties of materials, food and related products | ●current |
| HLTPAT006 | Receive, prepare and dispatch pathology specimens | !not current |
| MSL904003 | Perform standard calibrations | ●current |
| MSL914002 | Prepare practical science classes and demonstrations | ●current |
| MSL924006 | Use laboratory application software | ●current |
| MSL934010 | Maintain and control stocks | ●current |
| MSL953005 | Receive and prepare samples for testing | ●current |
| MSL954005 | Prepare mineral samples for analysis | ●current |
| MSL954006 | Relate anatomical and physiological features to laboratory samples | ●current |
| MSL954007 | Obtain representative samples in accordance with sampling plan | ●current |
| MSL973021 | Conduct field-based acceptance tests for construction materials | ●current |
| MSL973022 | Conduct laboratory-based acceptance tests for construction materials | ●current |
| MSL973025 | Perform basic tests | ●current |
| MSL973026 | Prepare working solutions | ●current |
| MSL973027 | Perform techniques that prevent cross-contamination | ●current |
| MSL973028 | Perform microscopic examination | ●current |
| MSL973029 | Perform histological procedures | ●current |
| MSL974016 | Perform physical and mechanical tests | ●current |
| MSL974018 | Conduct geotechnical site investigations | ●current |
| MSL974022 | Undertake environmental field-based monitoring | ●current |
| MSL974023 | Capture and manage scientific images | ●current |
| MSL974026 | Perform tests to determine the properties of construction materials | ●current |
| MSL974028 | Classify soils | ●current |
| MSL974029 | Operate an automated mineral analysis system | ●current |
| MSL974031 | Prepare, standardise and use solutions | ●current |
| MSL974032 | Perform chemical tests and procedures | ●current |
| MSL974033 | Perform food tests | ●current |
Show the remaining 12 elective units
| Code | Unit | In this product |
|---|---|---|
| MSL974034 | Perform biological procedures | ●current |
| MSL974035 | Prepare tissue or cell cultures | ●current |
| MSL974036 | Process body fluid specimens using a point of care testing device | ●current |
| MSL974037 | Triage and allocate tissue specimens | ●current |
| MSL974038 | Use techniques to complete simple tissue specimen transfers | ●current |
| MSL975057 | Perform histological tests | ●current |
| MSL975062 | Perform microbiological tests | ●current |
| MSL975066 | Apply routine chromatographic techniques | ●current |
| MSL975069 | Apply routine spectrometric techniques | ●current |
| MSL975073 | Perform laboratory-based ecological techniques | ●current |
| MSMENV472 | Implement and monitor environmentally sustainable work practices | ●current |
| TAEDEL311 | Provide work skill instruction | ●current |
Core and elective are the register's own flags on the unit grid of the release read here. "Not current" means training.gov.au no longer recommends that unit for use inside this product — it does not say anything about the product itself.
Source: this product on training.gov.au, Australia's national training register — or go straight to the units it requires. The rule itself is item 14 of F2025L00355, and ASQA publishes the extensions it has granted. Read on 28 August 2026 UTC. Every code, title, date, status and equivalence flag on this page is the register's; nothing here is estimated or inferred, and where the register publishes nothing we say so.
Every MSL training product on the register · Search all training products
Deliver this? We read the register nightly — get the free breakdown of your whole scope, and hear the day MSL40122 or anything else on it is superseded.
No account, no card. We never ask for anything about your learners. Your address gets this one report — no list, no marketing — and the scope watch only if you tick the box, with one click to stop it.