Where the register points next
training.gov.au points at nothing after MSM50316: it is the current product, and no replacement is listed.
What the register says changed
These are the mapping notes training.gov.au attaches to each supersession, quoted as the register writes them. They are the only public record of what actually changed between two versions.
Official documents on the register
What training.gov.au lists for MSM50316 and for its training package MSM (release 9.0), with the name and date the register publishes for each file. We link them; we have not read them, and nothing on this page is taken from their contents.
Is MSM50316 on your scope?
This page is the register's record of one product. What it cannot tell you is whether MSM50316 sits on your own scope today, or what else on that scope has moved without anyone noticing. Enter your RTO number and we read every product on your live scope against training.gov.au and tell you which ones are superseded and which replacements the register flags not equivalent.
Whether a supersession requires anything of you, and what, sits with you and your regulator. This page maps what the register records; it does not make that judgement. If the difference between an equivalent and a non-equivalent replacement is the question, we wrote it up in equivalent vs not equivalent.
What MSM50316 is made of
training.gov.au lists 65 units for MSM50316: 1 core and 64 elective. To complete it, the register publishes a rule of 1 core unit plus 9 electives — 10 units in all.
⚑register contradictionListed in MSM50316: 2 units the register itself has deleted, with no replacement published2
MSM50316 is current and the register publishes its unit grid. For these units the register also publishes, on their own record, a status that is not current and an empty replacement list. Both statements are the register's own. MSM50316 lists 44 units more that the register no longer recommends as current, but for those it does publish a replacement: they are not part of this count.
- PMASUP620↗□electiveManage environmental management systemThe register lists PMASUP620 in MSM50316 and has had it deleted since 4 May 2021. It publishes no replacement.
- TLIL5055↗□electiveManage a supply chainThe register lists TLIL5055 in MSM50316 and has had it deleted since 26 October 2020. It publishes no replacement.
Read from the unit grid training.gov.au publishes for MSM50316 (release 5, 4 September 2020) and from each unit's own record on the same register. We do not say what to put in their place: the register publishes no replacement, and which elective covers the gap is a packaging-rules decision for your RTO.
Core units 1 listed
| Code | Unit | In this product |
|---|---|---|
| MSMENV472 | Implement and monitor environmentally sustainable work practices | ●current |
Elective units 64 listed
| Code | Unit | In this product |
|---|---|---|
| BSBADM502 | Manage meetings | !not current |
| BSBFIM501 | Manage budgets and financial plans | !not current |
| BSBINM501 | Manage an information or knowledge management system | !not current |
| BSBLDR402 | Lead effective workplace relationships | !not current |
| BSBLED401 | Develop teams and individuals | !not current |
| BSBMGT401 | Show leadership in the workplace | !not current |
| BSBMGT403 | Implement continuous improvement | !not current |
| BSBMGT502 | Manage people performance | !not current |
| BSBMGT605 | Provide leadership across the organisation | !not current |
| BSBWHS401 | Implement and monitor WHS policies, procedures and programs to meet legislative requirements | !not current |
| BSBWRK520 | Manage employee relations | !not current |
| BSBWRT401 | Write complex documents | !not current |
| FNSORG501 | Develop and manage a budget | ●current |
| MEM11007B | Administer inventory procedures | !not current |
| MEM11012B | Purchase materials | !not current |
| MEM11015B | Manage warehouse inventory system | !not current |
| MEM14001B | Schedule material deliveries | !not current |
| MEM15002A | Apply quality systems | !not current |
| MSL915003 | Provide information to customers | ●current |
| MSL936003 | Maintain quality system and continuous improvement processes within work or functional area | !not current |
| MSMENV672 | Develop workplace policy and procedures for environmental sustainability | ●current |
| MSMOPS401 | Trial new process or product | ●current |
| MSMSUP330 | Develop and adjust a production schedule | ●current |
| MSMSUP390 | Use structured problem-solving tools | ●current |
| MSMSUP400 | Develop and monitor quality systems | ●current |
| MSMWHS401 | Assess risk | ●current |
| MSMWHS503 | Maintain WHS management system | ●current |
| MSMWHS510 | Manage risk | ●current |
| MSS014009 | Evaluate sustainability impact of a work or process area | !not current |
| MSS015022 | Develop strategies for more sustainable use of resources | !not current |
Show the remaining 34 elective units
| Code | Unit | In this product |
|---|---|---|
| MSS402082 | Apply cost factors to work practices | !not current |
| MSS404054 | Apply statistics to operational processes | !not current |
| MSS404060 | Facilitate the use of planning software systems in a work area or team | !not current |
| MSS405009 | Manage a value stream | !not current |
| MSS405016 | Manage workplace learning | !not current |
| MSS405022 | Design a process layout | !not current |
| MSS405030 | Optimise cost of a product or service | !not current |
| MSS405031 | Undertake value analysis of product or process costs in terms of customer requirements | !not current |
| MSS405032 | Analyse cost implications of maintenance strategy | !not current |
| MSS405041 | Implement improvement systems in an organisation | !not current |
| MSS405053 | Manage application of six sigma for process control and improvement | !not current |
| MSS405054 | Determine and improve process capability | !not current |
| MSS405063 | Develop the application of enterprise control systems in an organisation | !not current |
| MSS405064 | Determine and establish information collection requirements and processes | !not current |
| MSS405075 | Facilitate the development of a new product | !not current |
| MSS405081 | Develop a proactive maintenance strategy | !not current |
| MSS405082 | Adapt a proactive maintenance strategy to the process operations sector | !not current |
| MSS405084 | Manage people relationships | !not current |
| MSS405088 | Plan, implement and monitor energy management | ●current |
| PMAOPS500 | Optimise production systems | ●current |
| PMASUP520 | Review procedures to minimise environmental impact of process | ●current |
| PMASUP620 | Manage environmental management system | !not current |
| PSPHRM004 | Implement workforce planning and succession strategies | !not current |
| TLIA5058 | Manage facility and inventory requirements | ●current |
| TLIL4059 | Implement asset management systems | ●current |
| TLIL5055 | Manage a supply chain | !not current |
| TLIP4013 | Implement and monitor logistics planning and processes | !not current |
| TLIR4003 | Negotiate a contract | !not current |
| TLIR4008 | Implement and supervise stocktaking procedures | ●current |
| TLIR4009 | Implement purchasing systems | !not current |
| TLIR4010 | Plan purchasing | !not current |
| TLIR5005 | Manage a contract | ●current |
| TLIR5006 | Develop, implement and review purchasing strategies | ●current |
| TLIX5015 | Establish supply chains | !not current |
Core and elective are the register's own flags on the unit grid of the release read here. "Not current" means training.gov.au no longer recommends that unit for use inside this product — it does not say anything about the product itself.
Source: this product on training.gov.au, Australia's national training register — or go straight to the units it requires. The rule itself is item 14 of F2025L00355, and ASQA publishes the extensions it has granted. Read on 13 October 2026 UTC. Every code, title, date, status and equivalence flag on this page is the register's; nothing here is estimated or inferred, and where the register publishes nothing we say so.
Every MSM training product on the register · Search all training products
Take this with you — one email confirming MSM50316 is current on the register today, and what starts the clock if it is ever superseded. Nothing scheduled after it.
No account, no card. Your address gets this one email — no list, no marketing. Cutoff alerts only ever come from a watch you start yourself — the box just records your yes now — and every alert has a one-click stop.
Deliver this? We read the register nightly — get the free breakdown of your whole scope, and, if you tick the watch below, an email when something on it approaches the date new enrolments stop or changes what you have to do.
No account, no card. We never ask for anything about your learners. Your address gets this one report — no list, no marketing — and the scope watch only if you tick the box, with one click to stop it.