UEE41720 Certificate IV in Rail - Communications and Network Systems

Currenttraining.gov.au: current

Australia's national training register lists UEE41720 as current. It publishes no end date for the currency period.

Product type
Qualification
Training package
UEE — Electrotechnology Training Package
Currency period ends
no end date published
Latest release
Release 3 · 20 December 2022 · 3 releases in all
Supersedes
UEE41711
Superseded by
nothing — no replacement listed

Where the register points next

training.gov.au points at nothing after UEE41720: it is the current product, and no replacement is listed.

What the register says changed

These are the mapping notes training.gov.au attaches to each supersession, quoted as the register writes them. They are the only public record of what actually changed between two versions.

  • UEE41711UEE41720equivalent4 October 2020

    The register records this supersession but attaches no note on what changed.

Is UEE41720 on your scope?

This page is the register's record of one product. What it cannot tell you is whether UEE41720 sits on your own scope today, or what else on that scope has moved without anyone noticing. Enter your RTO number and we read every product on your live scope against training.gov.au and tell you which ones are superseded and which replacements the register flags not equivalent.

Public code, nothing else. We read your live scope from training.gov.au and answer here — nothing is stored unless you ask us to watch it.

Whether a supersession requires anything of you, and what, sits with you and your regulator. This page maps what the register records; it does not make that judgement. If the difference between an equivalent and a non-equivalent replacement is the question, we wrote it up in equivalent vs not equivalent.

What UEE41720 is made of

training.gov.au lists 41 units for UEE41720: 16 core and 25 elective. The register does not publish a completion rule in units for this product, so we do not state one. How many of the electives are required is in the packaging rules on training.gov.au.

Core units 16 listed

CodeUnitIn this product
UEECD0007Apply work health and safety regulations, codes and practices in the workplacecurrent
UEECD0010Compile and produce an energy sector detailed reportcurrent
UEECD0016Document and apply measures to control WHS risks associated with electrotechnology workcurrent
UEECD0019Fabricate, assemble and dismantle utilities industry componentscurrent
UEECD0024Implement and monitor energy sector WHS policies and procedurescurrent
UEECD0027Participate in development and follow a personal competency development plancurrent
UEECD0043Solve problems in direct current circuitscurrent
UEECD0051Use drawings, diagrams, schedules, standards, codes and specificationscurrent
UEEEC0028Fault find and repair complex power suppliescurrent
UEEEC0060Repairs basic electronic apparatus faults by replacement of componentscurrent
UEEEC0066Troubleshoot amplifiers in an electronic apparatuscurrent
UEEEC0067Troubleshoot basic amplifier circuitscurrent
UEEEC0069Troubleshoot digital sub-systemscurrent
UEEEC0074Troubleshoot resonance circuits in an electronic apparatuscurrent
UEEEC0075Troubleshoot single phase input d.c power suppliescurrent
UEERE0015Implement and monitor energy sector environmental and sustainable policies and procedurescurrent

Elective units 25 listed

CodeUnitIn this product
BSBOPS203Deliver a service to customerscurrent
CPCWHS1001Prepare to work safely in the construction industrycurrent
HLTAID009Provide cardiopulmonary resuscitationcurrent
ICTICT214Operate application software packagescurrent
UEECD0011Comply with scheduled and preventative maintenance program processescurrent
UEECD0035Provide basic instruction in the use of electrotechnology apparatuscurrent
UEECO0002Maintain documentationcurrent
UEECO0015Provide quotations for installation or service jobscurrent
UEECO0017Source and purchase material/parts for installation or service jobscurrent
UEECS0033Use engineering applications software on personal computerscurrent
UEEDV0004Install and connect data and voice communication equipmentcurrent
UEEDV0005Install and maintain cabling for multiple access to telecommunication servicescurrent
UEEDV0006Install and modify optical fibre performance data communication cablingcurrent
UEEDV0008Install, modify and verify coaxial and structured communication copper cablingcurrent
UEEDV0009Select and arrange data and voice equipment for local area networkscurrent
UEEDV0010Select and arrange equipment for wireless communication networkscurrent
UEEDV0012Set up and configure the wireless capabilities of communications and data storage devicescurrent
UEEEC0019Develop software solutions for microcontroller-based systemscurrent
UEEEC0022Diagnose and rectify faults in camera circuits and equipmentcurrent
UEEEC0023Diagnose and rectify faults in digital transmission circuits and systemscurrent
UEEEC0024Diagnose and rectify faults in electronic display circuitscurrent
UEEEC0025Diagnose and rectify faults in recording and replay equipmentcurrent
UEEEC0033Fault find and repair navigation systemscurrent
UEEEC0051Program and commission commercial video/audio systemscurrent
UEEEC0061Set up and adjust commercial radio frequency (RF) transmission and reception systemscurrent

Core and elective are the register's own flags on the unit grid of the release read here. "Not current" means training.gov.au no longer recommends that unit for use inside this product — it does not say anything about the product itself.

Source: this product on training.gov.au, Australia's national training register — or go straight to the units it requires. The rule itself is item 14 of F2025L00355, and ASQA publishes the extensions it has granted. Read on 28 August 2026 UTC. Every code, title, date, status and equivalence flag on this page is the register's; nothing here is estimated or inferred, and where the register publishes nothing we say so.

Every UEE training product on the register · Search all training products

Deliver this? We read the register nightly — get the free breakdown of your whole scope, and hear the day UEE41720 or anything else on it is superseded.

No account, no card. We never ask for anything about your learners. Your address gets this one report — no list, no marketing — and the scope watch only if you tick the box, with one click to stop it.