UET20519 Certificate II in National Broadband Network Cabling (Electricity Supply Industry Assets)

deletedthe status token training.gov.au records

Transition clockClosed to new enrolments

Sector-wide: the item 14 cut-off, measured across every live scope · the repealed 12-month rule

The status above is the one training.gov.au records for UET20519, written exactly as the register writes it. It is not one of the three we put into words, so we leave it in the register's own terms.

Product type
Qualification
Training package
UET — Transmission, Distribution and Rail Sector
Currency period ends
18 September 2021
Latest release
Release 1 · 25 September 2019
Supersedes
UET20511
Superseded by
nothing — no replacement listed

Where the register points next

training.gov.au does not publish a supersession path from UET20519. There is no chain to follow from here.

What the register says changed

These are the mapping notes training.gov.au attaches to each supersession, quoted as the register writes them. They are the only public record of what actually changed between two versions.

  • UET20511UET20519equivalent24 September 2019

    The register records this supersession but attaches no note on what changed.

Is UET20519 on your scope?

This page is the register's record of one product. What it cannot tell you is whether UET20519 sits on your own scope today, or what else on that scope has moved without anyone noticing. Enter your RTO number and we read every product on your live scope against training.gov.au and tell you which ones are superseded and which replacements the register flags not equivalent.

Public code, nothing else. We read your live scope from training.gov.au and answer here — nothing is stored unless you ask us to watch it.

Whether a supersession requires anything of you, and what, sits with you and your regulator. This page maps what the register records; it does not make that judgement. If the difference between an equivalent and a non-equivalent replacement is the question, we wrote it up in equivalent vs not equivalent.

What UET20519 is made of

training.gov.au lists 27 units for UET20519: 7 core and 20 elective. The register does not publish a completion rule in units for this product, so we do not state one. How many of the electives are required is in the packaging rules on training.gov.au.

Core units 7 listed

CodeUnitIn this product
UEENEEE101AApply Occupational Health and Safety regulations, codes and practices in the workplacenot current
UEENEEE102AFabricate, assemble and dismantle utilities industry componentsnot current
UEENEEE105AFix and secure electrotechnology equipmentnot current
UEENEEE137ADocument and apply measures to control OHS risks associated with electrotechnology worknot current
UEENEEK142AApply environmentally and sustainable procedures in the energy sectornot current
UETTDREL14Working safely near live electrical apparatus as a non-electrical workernot current
UETTDRIS81Install telecommunications infrastructure on electricity supply industry assetsnot current

Elective units 20 listed

CodeUnitIn this product
CPCCCM2007Use explosive power toolscurrent
CPCCWHS1001Prepare to work safely in the construction industrynot current
HLTAID001Provide cardiopulmonary resuscitationnot current
HLTAID009Provide cardiopulmonary resuscitationcurrent
ICTCBL208Splice and terminate optical fibre cable for carriers and service providersnot current
ICTCBL210Install a telecommunications service to a buildingcurrent
RIIWHS202DEnter and work in confined spacesnot current
RIIWHS204DWork safely at heightsnot current
RIIWHS205DControl traffic with stop-slow batnot current
TLID3035Operate a boom type elevating work platformcurrent
TLILIC0005Licence to operate a boom-type elevating work platform (boom length 11 metres or more)current
UEENEEC001BMaintain documentationnot current
UEENEEC008BReceive and store materials and equipment for electrotechnology worknot current
UEENEEC010BDeliver a service to customersnot current
UEENEEE103ASolve problems in ELV single path circuitsnot current
UEENEEE104ASolve problems in d.c. circuitsnot current
UEENEEE151ATransport apparatus, equipment and materialsnot current
UEENEEF106ASolve problems in voice and data communications circuitsnot current
UEENEEF107ASet up and configure the wireless capabilities of communications and data storage devicesnot current
UETTDREL12Operate plant and equipment near live electrical conductors and apparatusnot current

Core and elective are the register's own flags on the unit grid of the release read here. "Not current" means training.gov.au no longer recommends that unit for use inside this product — it does not say anything about the product itself.

Source: this product on training.gov.au, Australia's national training register — or go straight to the units it requires. The rule itself is item 14 of F2025L00355, and ASQA publishes the extensions it has granted. Read on 28 August 2026 UTC. Every code, title, date, status and equivalence flag on this page is the register's; nothing here is estimated or inferred, and where the register publishes nothing we say so.

Every UET training product on the register · Search all training products

Is UET20519 still on your scope? Type your RTO code and get the free breakdown — every superseded product on your live scope, and whether the register flags each replacement equivalent.

No account, no card. We never ask for anything about your learners. Your address gets this one report — no list, no marketing — and the scope watch only if you tick the box, with one click to stop it.