Where the register points next
training.gov.au points at nothing after MEM31219: it is the current product, and no replacement is listed.
What the register says changed
These are the mapping notes training.gov.au attaches to each supersession, quoted as the register writes them. They are the only public record of what actually changed between two versions.
Is MEM31219 on your scope?
This page is the register's record of one product. What it cannot tell you is whether MEM31219 sits on your own scope today, or what else on that scope has moved without anyone noticing. Enter your RTO number and we read every product on your live scope against training.gov.au and tell you which ones are superseded and which replacements the register flags not equivalent.
Whether a supersession requires anything of you, and what, sits with you and your regulator. This page maps what the register records; it does not make that judgement. If the difference between an equivalent and a non-equivalent replacement is the question, we wrote it up in equivalent vs not equivalent.
What MEM31219 is made of
training.gov.au lists 37 units for MEM31219: 28 core and 9 elective. The register does not publish a completion rule in units for this product, so we do not state one. How many of the electives are required is in the packaging rules on training.gov.au.
Core units 28 listed
| Code | Unit | In this product |
|---|---|---|
| MEM10016 | Terminate and test electrical wiring and accessories | ●current |
| MEM10018 | Select cable types and sizes to suit loads and electrical installation environment | ●current |
| MEM10019 | Select circuit protection devices by type and rating, fit to switchboards and install earthing | ●current |
| MEM10020 | Install low voltage cabling and fit-off accessories, appliances and equipment | ●current |
| MEM10021 | Inspect, test and verify electrical installations | ●current |
| MEM10022 | Commission and decommission high and low voltage equipment or installations | ●current |
| MEM10023 | Design and connect control switching of circuits for building services and industrial equipment | ●current |
| MEM10024 | Install and troubleshoot luminaires and ancillary equipment | ●current |
| MEM10025 | Undertake a capstone assessment | ●current |
| MEM12023 | Perform engineering measurements | ●current |
| MEM12024 | Perform computations | ●current |
| MEM13015 | Work safely and effectively in manufacturing and engineering | ●current |
| MEM13017 | Apply safety practices, procedures and compliance standards associated with licensed electrical work | ●current |
| MEM14006 | Plan work activities | ●current |
| MEM16006 | Organise and communicate information | ●current |
| MEM16008 | Interact with computing technology | ●current |
| MEM17003 | Assist in the provision of on-the-job training | ●current |
| MEM18001 | Use hand tools | ●current |
| MEM18100 | Fault-find, test and rectify AC machines and circuits | ●current |
| MEM18102 | Fault-find, test and rectify single and three-phase transformers | ●current |
| MEM18103 | Fault-find, test and rectify electrical circuits and equipment | ●current |
| MEM18104 | Dismantle, replace and assemble electrical components and equipment | ●current |
| MSMENV272 | Participate in environmentally sustainable work practices | ●current |
| UEENEEE101A | Apply Occupational Health and Safety regulations, codes and practices in the workplace | !not current |
| UEENEEE104A | Solve problems in d.c. circuits | !not current |
| UEENEEE107A | Use drawings, diagrams, schedules, standards, codes and specifications | !not current |
| UEENEEG101A | Solve problems in electromagnetic devices and related circuits | !not current |
| UEENEEG102A | Solve problems in low voltage a.c. circuits | !not current |
Elective units 9 listed
| Code | Unit | In this product |
|---|---|---|
| MEM05001 | Perform manual soldering/desoldering - electrical/electronic components | ●current |
| MEM05012 | Perform routine manual metal arc welding | ●current |
| MEM05050 | Perform routine gas metal arc welding | ●current |
| MEM07032 | Use workshop machines for basic operations | ●current |
| MEM13016 | Work in hazardous areas | ●current |
| MEM18105 | Disconnect and reconnect high voltage fixed wired equipment | ●current |
| MEM18106 | Terminate communication and data cables | ●current |
| MEM18108 | Troubleshoot analog and digital electronic equipment | ●current |
| MEM18109 | Troubleshoot instrumentation systems and equipment | ●current |
Core and elective are the register's own flags on the unit grid of the release read here. "Not current" means training.gov.au no longer recommends that unit for use inside this product — it does not say anything about the product itself.
Source: this product on training.gov.au, Australia's national training register — or go straight to the units it requires. The rule itself is item 14 of F2025L00355, and ASQA publishes the extensions it has granted. Read on 28 August 2026 UTC. Every code, title, date, status and equivalence flag on this page is the register's; nothing here is estimated or inferred, and where the register publishes nothing we say so.