UEE31211 Certificate III in Instrumentation and Control

Supersededtraining.gov.au: supersededEquivalent

The currency period for UEE31211 ended on 3 October 2020 — 6 years ago. It names one replacement below, with the equivalence it declares for each.

Transition clockOpen for new enrolmentsClosing to new enrolments soonClosed to new enrolments

For an RTO registered by ASQA, new enrolments are not permitted today, unless ASQA has approved otherwise — for your organisation, for a class of RTOs, or for all RTOs. The one-year point this rule counts from — one year from the date the replacement was included on the National Register — fell earlier, on 5 October 2021. That date is arithmetic, not a day on which this instrument prohibited anything: s 14(1)(a)(i) of the National Vocational Education and Training Regulator (Compliance Standards for NVR Registered Training Organisations and Fit and Proper Person Requirements) Instrument 2025 (F2025L00355) commenced on 1 July 2025 and imposes nothing before then. RTOs registered by VRQA in Victoria or by the TAC in Western Australia are not covered by it.

Learners already enrolled have no fixed deadline: they complete the product and are issued their AQF certification, or transfer to the replacement, in a timely manner (ASQA guidance, read live 25 August 2026).

A second obligation follows from the same fact: under s 7(2)(c) of the same instrument, advertising may refer to a superseded product only while it is on scope and new enrolments are permitted. For an RTO registered by ASQA, new enrolments in this product are not permitted today, so a course page advertising it is not permitted either — and if ASQA approves a later enrolment date, that moves with it.

Sector-wide: the item 14 cut-off, measured across every live scope · the repealed 12-month rule

Product type
Qualification
Training package
UEE11 — Electrotechnology Training Package
Currency period ends
3 October 2020
Latest release
Release 4 · 17 April 2014 · 4 releases in all
Supersedes
UEE31210
Superseded by
UEE31220 equivalent

Where the register points next

Each step below is one supersession training.gov.au publishes between two products. The label on the rail is the equivalence the register declares for that step — not our reading of it.

  1. UEE31211Superseded — equivalentCertificate III in Instrumentation and Control
  2. equivalent
  3. UEE31220Superseded — equivalentCertificate III in Instrumentation and Control
  4. equivalent
  5. UEE31225CurrentCertificate III in Instrumentation and Control

What the register says changed

These are the mapping notes training.gov.au attaches to each supersession, quoted as the register writes them. They are the only public record of what actually changed between two versions.

  • UEE31210UEE31211equivalent15 March 2012

    The register records this supersession but attaches no note on what changed.

  • UEE31211UEE31220equivalent4 October 2020

    The register records this supersession but attaches no note on what changed.

Official documents on the register

What training.gov.au lists for UEE31211 and for its training package UEE11 (release 1.5), with the name and date the register publishes for each file. We link them; we have not read them, and nothing on this page is taken from their contents.

  • UEE31211_R4.pdfUEE31211 release 4 · product document · published 22 December 2022
  • UEE31211_R4.docxUEE31211 release 4 · product document · published 26 November 2024

Is UEE31211 on your scope?

This page is the register's record of one product. What it cannot tell you is whether UEE31211 sits on your own scope today, or what else on that scope has moved without anyone noticing. Enter your RTO number and we read every product on your live scope against training.gov.au and tell you which ones are superseded and which replacements the register flags not equivalent.

Public code, nothing else. We read your live scope from training.gov.au and answer here — we keep neither the code nor the answer; what remains is the two-minute abuse counter described on our privacy page.

Whether a supersession requires anything of you, and what, sits with you and your regulator. This page maps what the register records; it does not make that judgement. If the difference between an equivalent and a non-equivalent replacement is the question, we wrote it up in equivalent vs not equivalent.

What UEE31211 is made of

training.gov.au lists 61 units for UEE31211: 23 core and 38 elective. The register does not publish a completion rule in units for this product, so we do not state one. How many of the electives are required is in the packaging rules on training.gov.au.

Core units 23 listed

CodeUnitIn this product
UEENEEC024BParticipate in instrumentation and control work and competency development activitiesnot current
UEENEEE101AApply Occupational Health and Safety regulations, codes and practices in the workplacenot current
UEENEEE102AFabricate, assemble and dismantle utilities industry componentsnot current
UEENEEE104ASolve problems in d.c. circuitsnot current
UEENEEE105AFix and secure electrotechnology equipmentnot current
UEENEEE107AUse drawings, diagrams, schedules, standards, codes and specificationsnot current
UEENEEE119ASolve problems in multiple path extra low voltage (ELV) a.c. circuitsnot current
UEENEEE137ADocument and apply measures to control OHS risks associated with electrotechnology worknot current
UEENEEI101AUse instrumentation drawings, specification, standards and equipment manualsnot current
UEENEEI102ASolve problems in pressure measurement components and systemsnot current
UEENEEI103ASolve problems in density/level measurement components and systemsnot current
UEENEEI104ASolve problems in flow measurement components and systemsnot current
UEENEEI105ASolve problems in temperature measurement components and systemsnot current
UEENEEI106ASet up and adjust PID control loopsnot current
UEENEEI107AInstall instrumentation and control cabling and tubingnot current
UEENEEI108AInstall instrumentation and control apparatus and associated equipmentnot current
UEENEEI110ASet up and adjust advanced PID process control loopsnot current
UEENEEI111AFind and rectify faults in process final control elementsnot current
UEENEEI112AVerify compliance and functionality of instrumentation and control installationsnot current
UEENEEI113ASetup and configure Human-Machine Interface (HMI) and industrial networksnot current
UEENEEI150ADevelop, enter and verify discrete control programs for programmable controllersnot current
UEENEEK142AApply environmentally and sustainable procedures in the energy sectornot current
UEENEEP013ADisconnect - reconnect control devices connected to low voltage installation wiringnot current

Elective units 38 listed

CodeUnitIn this product
CPCCOHS1001AWork safely in the construction industrynot current
HLTAID001Provide cardiopulmonary resuscitationnot current
HLTAID003Provide first aidnot current
HLTAID009Provide cardiopulmonary resuscitationcurrent
HLTAID011Provide First Aidcurrent
UEENEEC001BMaintain documentationnot current
UEENEEC002BSource and purchase material/parts for installation or service jobsnot current
UEENEEC003BProvide quotations for installation or service jobsnot current
UEENEEC010BDeliver a service to customersnot current
UEENEED101AUse computer applications relevant to a workplacenot current
UEENEED104AUse engineering applications software on personal computersnot current
UEENEEE009BComply with scheduled and preventative maintenance program processesnot current
UEENEEE020BProvide basic instruction in the use of electrotechnology apparatusnot current
UEENEEH102ARepairs basic electronic apparatus faults by replacement of componentsnot current
UEENEEH111ATroubleshoot single phase input d.c. power suppliesnot current
UEENEEH112ATroubleshoot digital sub-systemsnot current
UEENEEI114ATrouble shoot process control systemsnot current
UEENEEI115ATrouble shooting in medical equipment control systemsnot current
UEENEEI117ACalibrate, adjust and test measuring instrumentsnot current
UEENEEI118ASet up weighting measuring and control instrumentsnot current
UEENEEI131ASet up gas analysis measuring and control instrumentsnot current
UEENEEI132ASet up water analysis measuring and control instrumentsnot current
UEENEEI133ASet up scientific analysis measuring and control instrumentsnot current
UEENEEM019AAttend to breakdowns in hazardous areas - coal miningnot current
UEENEEM020AAttend to breakdowns in hazardous areas - gas atmospheresnot current
UEENEEM021AAttend to breakdowns in hazardous areas - dust atmospheresnot current
UEENEEM022AAttend to breakdowns in hazardous areas - pressurisationnot current
UEENEEM023AInstall explosion-protected equipment and wiring systems - coal miningnot current
UEENEEM024AInstall explosion-protected equipment and wiring systems - gas atmospheresnot current
UEENEEM025AInstall explosion-protected equipment and wiring systems - dust atmospheresnot current
Show the remaining 8 elective units
CodeUnitIn this product
UEENEEM026AInstall explosion-protected equipment and wiring systems - pressurisationnot current
UEENEEM027AMaintain equipment in hazardous areas - coal miningnot current
UEENEEM028AMaintain equipment in hazardous areas - gas atmospheresnot current
UEENEEM029AMaintain equipment in hazardous areas - dust atmospheresnot current
UEENEEM030AMaintain equipment in hazardous areas - pressurisationnot current
UEENEEM076AUse and maintain the integrity of a portable gas detection devicenot current
UEENEEM077AInstall and maintain the integrity of fixed gas detection equipmentnot current
UEENEEM080AReport on the integrity of explosion-protected equipment in a hazardous areanot current

Core and elective are the register's own flags on the unit grid of the release read here. "Not current" means training.gov.au no longer recommends that unit for use inside this product — it does not say anything about the product itself.

Source: this product on training.gov.au, Australia's national training register — or go straight to the units it requires. The rule itself is item 14 of F2025L00355, and ASQA publishes the extensions it has granted. Read on 14 October 2026 UTC. Every code, title, date, status and equivalence flag on this page is the register's; nothing here is estimated or inferred, and where the register publishes nothing we say so.

Every UEE training product on the register · Search all training products

Take this with you — one email with this page's clock as the register states it today. Nothing scheduled after it.

No account, no card. Your address gets this one email — no list, no marketing. Cutoff alerts only ever come from a watch you start yourself — the box just records your yes now — and every alert has a one-click stop.

Is UEE31211 still on your scope? Type your RTO code and get the free breakdown — every superseded product on your live scope, and whether the register flags each replacement equivalent.

No account, no card. We never ask for anything about your learners. Your address gets this one report — no list, no marketing — and the scope watch only if you tick the box, with one click to stop it.